BGWPT - REGULAR GASOLINE

Product Identification

Product ID:REGULAR GASOLINE
MSDS Date:03/28/1990
FSC:9130
NIIN:00-264-6218
MSDS Number: BGWPT

Responsible Party
COASTAL EAGLE POINT OIL CO
9 GREENWAY PLAZA
HOUSTON, TX 77046
US

Emergency Phone: 713-877-1400

Info Phone: 713-877-1400

Preparer: DELNO D. MALZAHN

Cage: 0BDU2

Contractor
COASTAL EAGLE POINT OIL CO, THE COSTAL CORP.
HOUSTON, TX 77046 US

Telephone: 713-877-1400

Cage: 0BDU2

Ingredients

BENZENE (SARA III)

CAS: 71-43-2

RTECS: CY1400000

Fraction By Weight: 0 - 5%

OSHA PEL 1PPM/5STEL;1910.1028

ACGIH TLV: 10 PPM; A2; 9192

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 0 - 25%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 0 - 25%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYL BENZENE (SARA III)

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: 0 - 5%

OSHA PEL 100 PPM/125 STEL

ACGIH TLV: 100 PPM/125STEL 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HEXANE (N-HEXANE)

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: 0 - 3%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


1,2,4-TRIMETHYLBENZENE (SARA III)

CAS: 95-63-6

RTECS: DC3325000

Fraction By Weight: 0 -5%

OSHA PEL 25 PPM

ACGIH TLV: 25 PPM; 9192


CUMENE (SARA III)

CAS: 98-82-8

RTECS: GR8575000

Fraction By Weight: 1%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 50 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CYCLOHEXANE (SARA III)

CAS: 110-82-7

RTECS: GU6300000

Fraction By Weight: 1%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM, 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


BUTANE

CAS: 106-97-8

RTECS: EJ4200000

Fraction By Weight: <9%

OSHA PEL 800 PPM

ACGIH TLV: 800 PPM; 9192


PENTANE

CAS: 109-66-0

RTECS: RZ9450000

Fraction By Weight: <5%

OSHA PEL 1000 PPM/750 STEL

ACGIH TLV: 600 PPM/750STEL;9293


TERT-BUTYL ALCOHOL (SARA III)

CAS: 75-65-0

RTECS: EO1925000

Fraction By Weight: 0 - 10%

OSHA PEL 100 PPM

ACGIH TLV: 100PPM 9394


METHYL TERT-BUTYL ETHER (SARA III)

CAS: 1634-04-4

RTECS: KN5250000

Fraction By Weight: 0 - 15%

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


HEXANE (ISOMERS OTHER THAN N-HEXANE)

Fraction By Weight: <8.5%


TETRAETHYL LEAD/ TETRAMETHYL LEAD MIXTURE

Fraction By Weight: <0.0038%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:EYES: SLIGHT TO MODERATE IRRITATION.
SKIN: MODERATELY IRRITATING. INHALATION: IRRITATING TO MOUCOUS
MEMBRANES AND RESPIRATORY TRACT. INGESTION: STOMACH IRRITATION,
LOSS OF CONSCIOUSNESS AND CENTRAL NERVOUS SYSTEM DEPRESSION.
Explanation of Carcinogenicity:THIS PRODUCT CONTAINS BENZENE.
Effects of Overexposure:SKIN: REDNESS, DRYING OF SKIN. INHALATION:
HEADACHE, NAUSEA, DROWSINESS, FATIGUE, PNEUMONITIS, PULMONARY
EDEMA, COMA AND RESPIRATORY ARREST. GASTRITIS, HEADACHE, NAUSEA,
DROWSINESS, LOSS OF CONSCIOU SNESS, CONVULSIONS, CYANOSIS,
PNEUMONITIS, PULMONARY EDEMA, CAPILLARY HEMORRHAGING OF THE LUNGS
AND INTERNAL ORGANS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES,
INCLUDING UNDER THE EYELIDS. CONTACT A PHYSICIAN IMMEDIATELY. SKIN:
REMOVE CONTAMINATED CLOTHING AND SHOES. WASH AFFECTED AREAS WITH
SOAP AND FLUSH WITH LARGE AMOUNTS OF WATER FOR 15 TO 20 MINUTES.
INHALATION: REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED, APPLY
ARTIFICIAL RESPIRATION. INGESTION: DO NOT INDUCE VOMITING. PREVENT
ASPIRATION.

Fire Fighting

Flash Point Method:TCC
Flash Point:=-42.8C, -45.F
Autoignition Temp:=257.2C, 495.F
Lower Limits:1.4
Upper Limits:7.6
Extinguishing Media:DRY CHEMICAL, FOAM, OR CARBON DIOXIDE.
Fire Fighting Procedures:USE A SMOTHERING TECHNIQUE FOR EXTINGUISHING
FIRE OF THIS FLAMMABLE LIQUID. DO NOT USE A FORCED WATER STREAM.
USE A WATER SPRAY TO COOL CONTAINERS.
Unusual Fire/Explosion Hazard:FIRE-FIGHTERS SHOULD WEAR SELF-CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING. *FLOWING GASOLINE
CAN BE IGNITED BY SELF GENERATED STATIC ELECTRICITY

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT OR IGNITION INCLUDING
INTERNAL COMBUSTION ENGINES AND POWER TOOLS. CLEAN-UP SPILL, BUT DO
NOT FLUSH TO SEWER OR SURFACE WATER. VENTILATE AREA AND AVIOD
BREATHING VAPORS AND MIST S.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINERS IN
A DRY COOL PLACE. GROUND AND BOND ALL TRANSFER AND STORAGE
EQUIPMENT TO PREVENT STATIC SPARKS .
Other Precautions:EMPTY CONTAINERS MAY STILL CONTAIN RESIDUE.

Exposure Controls

Respiratory Protection:USE APPROVED RESPIRATORY PROTECTIVE EQUIPMENT
FOR CLEANING LARGE SPILLS OR UPON ENTRY INTO LARGE TANKS, VESSELS,
AND OTHER DESIGNATED CONFINED SPACES OR IN ANY SITUATIONS WHERE
AIRBORNE CONCENTRATIONS MAY EXCEED OCCUPATIONAL EXPOSURE LIMITS
Ventilation:PROVIDE ADEQUATE GENERAL AND LOCAL VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL SAFETY GLASSES OR GOGGLES.
Other Protective Equipment:NONE
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING THIS PRODUCT.
Supplemental Safety and Health
GASOLINE IS TO BE USED AS MOTOR FUEL ONLY. NEVER USE AS A CLEANING
SOLVENT OR DEGREASER. USE EXPLOSION-PROOF ELECTRICAL EQUIPMENT. NO
SMOKING SHOULD BE ALLOWED IN AREA OF USE.

Chemical Properties

HCC:F1
Boiling Pt:=26.7C, 80.F
Vapor Pres:325 - 525
Vapor Density:3 - 4
Spec Gravity:0.7 - 0.77
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AROMATIC ODOR WITH BRONZE FLUID.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, HALOGENS, STRONG ACIDS AND ALKALINES.
Stability Condition to Avoid:HEAT, SPARKS, FLAME, AND BUILD-UP OF
STATIC ELECTRICITY.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
HYDROCARBONS AND LEAD OXIDES.

Disposal

Waste Disposal Methods:DISPOSE THROUGH A LICENSED WASTE DISPOSAL
COMPANY. FOLLOW FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.